Model number: LMM-5T-DV-B
Features
- Utilizes Lutron Clear Connect RF technology
- Compatibility: RA2 select, RadioRA 2 or HomeWorks
- Surge Protection: Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits
- Frequency band: 868 MHz Limited
Mounting: Mounts to an electrical junction box through a 1/2 in (21 mm) knockout opening.
Power : 220–240 V~ 50/60 Hz 5A
Typical Power Consumption: < 1.0 W Typical power test conditions: all loads off
Regulatory Approvals : ULR, UL 2043 Plenum Rated, FCC Approved.
Environment Ambient operating temperature: 0 °C to 40 °C
Ambient operating humidity: 0% to 90% humidity, non-condensing. Indoor use only
Communications: Operates using Clear Connect RF technology for reliable wireless communication.RF range is 30 ft (9 m) from repeaters
Control Link Load: 0–10 V-Maximum Load: 60 mA, source or sink automatically configures.
Control link compatible: with ANSI E1.3 2001 (R2006), IEC 60929 Annex E.
Switched Maximum Load: 5 A lighting. No minimum load requirements. Load types include, but are not limited to: MLV, ELV, Incandescent, Magnetic fluorescent, Electronic fluorescent and LEDs.